h6. [[Econet]] h6(. » [[Econet SWI Calls|SWI Calls]] h6((. » Econet_StartTransmit h2. Econet_StartTransmit h5. (SWI &40006) |_<^{width:4em}. Entry | | |<^. R0 |<^. Flag byte | |<^. R1 |<^. Port number | |<^. R2 |<^. Station number | |<^. R3 |<^. Net number | |<^. R4 |<^. Pointer to data buffer | |<^. R5 |<^. Buffer size | |<^. R6 |<^. Retry count | |<^. R7 |<^. Delay (in centi-seconds) | |_<^{width:4em}. Exit | | |<^. R0 |<^. Handle | |<^. R1 |<^. Corrupted | |<^. R2 |<^. Pointer to buffer | |<^. R3 |<^. Station number | |<^. R4 |<^. Net number (or 0 if R3 on entry was the local net) | h4. Use The purpose of this call is to create a Transmit Control Block and starts a transmission. h4. Notes The data buffer should be in RMA or some other permanently available area of memory, due to the way in which the data is read. This SWI is re-entrant. h4. See also * [[Econet Technical Details]] * [[Econet_AbandonTransmit]] * [[Econet_DoTransmit]] * [[Econet_PollTransmit]]