h6. [[FileCore]] h6(. » [[FileCore SWI Calls|SWI Calls]] h6((. » [[FileCore_DiscOp]] h6(((. » FS Specific Errors h2. FS Specific Errors h2(#harddisc). Hard Disc Error Codes h4(#ide). Hard disc Error Codes (IDE Controller) |_<^{width:4em}. Value|_<^. Meaning| |<^. &02 |<^. Command aborted by controller | |<^. &07 |<^. Write fault | |<^. &08 |<^. Drive not ready | |<^. &09 |<^. Track 0 not found | |<^. &13 |<^. Uncorrected data error | |<^. &16 |<^. Sector ID field not found | |<^. &17 |<^. Bad block mark detected | |<^. &18 |<^. No data address mark | |<^. &20 |<^. No DRQ when expected | |<^. &21 |<^. Drive busy when commanded | |<^. &22 |<^. Drive busy on command completion | |<^. &23 |<^. Controller did not respond within timeout | |<^. &24 |<^. Unknown code in error register | |<^. &26 |<^. CRC error | h4(#st506). Hard disc Error Codes (old ST506 Controller) |_<^{width:4em}. Value|_<^. Meaning| |<^. &01|<^. Abort command accepted| |<^. &02|<^. Invalid command issued| |<^. &03|<^. Invalid command parameter| |<^. &04|<^. Head positioning, disc access, or drive check before SPC issued| |<^. &05|<^. TST command after SPC command| |<^. &06|<^. USELD for a drive has not been returned| |<^. &07|<^. Write fault detected by interface| |<^. &08|<^. Drive not ready| |<^. &09|<^. Seek complete timed out| |<^. &0A|<^. SEK, or disc access issued during a seek| |<^. &0B|<^. Next cylinder address is too big| |<^. &0C|<^. Invalid step rate: highest-speed seek specified in normal mode| |<^. &0D|<^. SEK, or disc access issued to drive with seek error| |<^. &0E|<^. Data overrun (memory is slower than the drive)| |<^. &0F|<^. Head address too high| |<^. &10|<^. Error correction code detected an error| |<^. &11|<^. CRC error in data area| |<^. &12|<^. Error correction code corrected an error| |<^. &13|<^. Error correction code failed in data area| |<^. &14|<^. In CMPD command data mismatched from host and disc| |<^. &15|<^. CRC in ID field (never generated)| |<^. &16|<^. ID search timed out| |<^. &17|<^. ID area has bad address mark| |<^. &18|<^. Missing address mark| |<^. &19|<^. Drive write protected| h2(#floppy). Floppy Disc Error Codes h4(#floppy710). Floppy discs Error Codes (710/711) |_<^{width:4em}. Value|_<^. Meaning| |<^. &01|<^. Fatal error, controller hardware error| |<^. &02|<^. Fatal error, command timed out; drive problem| |<^. &03|<^. Fatal error, track 0 not found; drive problem| |<^. &10|<^. Critical error, seek failed| |<^. &20|<^. Recoverable error, non specific command error| |<^. &21|<^. Data overrun| |<^. &22|<^. Data CRC error| |<^. &23|<^. Sector or ID not found| |<^. &24|<^. Missing address mark| h4(#floppy1772). Floppy discs Error Codes (1772) |_<^{width:4em}. Bit|_<^. Meaning| |<^. 0|<^. Drive busy| |<^. 1|<^. Track 0 found| |<^. 2|<^. Lost data| |<^. 3|<^. CRC error| |<^. 4|<^. Record not found| |<^. 5|<^. Write failed| |<^. 6|<^. Drive is write protected| |<^. 7|<^. Drive was already running| h4. See also * [[FileCore]] * [[FileCore_DiscOp]] * [[FileCore Error Numbers]]