Control lists are used with type 3 VIDC lists as a way of specifying extra settings. Each entry in the list is a pair of words, with the first word being the control index and the second word being the value.
Control index | Description | Values |
---|---|---|
1 | LCD mode | 0 => disable, 1 => enable |
2 | LCD dual panel mode | 0 => disable, 1 => enable |
3 | LCD offset register 0 | 0-255 |
4 | LCD offset register 1 | 0-255 |
5 | High res mode | 0 => disable, 1 => enable |
6 | DAC control setting | 0 => disable, 1 => enable (default) |
7 | RGB pedestals | bit 0 = R, bit 1 = G, bit 2 = B |
8 | External register value | 0-255 |
9 | H clock select | ? |
10 | R clock frequency | ? |
11 | DPMS state | 0-3, as MDF |
12 | Interlace setting | 0 => disable, 1 => enable |
13 | Output format | ? |
14 | Extra bytes | ? |